9
1. Sign in to Sage Accpac as user ADMIN with the correct password.
2. In the Administrative Services folder, double click on the icon “Data Activation”.
3. Answer “Yes” to Proceed and click on the application “ACCU-DART (V53B, V54A, etc).
4. Click the “Activate” button and then the “Proceed” button. You will see the ACCU-DART folder added to
the Sage Accpac desktop after the activation is completed. You are now ready to congure ACCU-DART.
In Sage Accpac ERP, Click on the ACCU-DART folder, then double click on the icon “Maintenance”. There are eight
selections:
1. RF Options Maintenance
2. Warehouse Maintenance
3. User Maintenance
4. Bar Code Maintenance
5. Label Maintenance
6. Worksheet Maintenance
7. Optional Fields
8. Purge Transactions
RF Options Maintenance
1. Double click on the icon “RF Options Maintenance”. The follow screen will open:
2. Select the Database Type (Microsoft SQL Server or Pervasive SQL)
3. Enter the Database Server Name in the ACCU-DART Company Set-Up window
For Microsoft SQL Server
To nd the correct Database Server Name:
a. On the computer/server where Microsoft SQL Server is physically installed, open the SQL Server
Enterprise Manager and right-click on “Microsoft SQL Servers”
b. Click on “About SQL Server Enterprise Manager…” and then click on “System Info…”
c. The system information box will open. The System Name is the Database Server Name
For Database User ID and Database Password elds, enter the MS SQL System Administrator’s user ID
and password.
OR
For Pervasive.SQL Server
To nd the correct Database Server Name:
a. On the computer/server where Pervasive.SQL server is physically installed, right-click on “My
Computer”
b. Click on “Properties”, and then click on the “Computer Name” tab.
c. The Computer Name screen will open. The Full Computer Name is the Database Server Name
Enter the Database Server name in the ACCU-DART Company Set-up window
**Do not enter a Database User ID or Database Password for Pervasive.SQL Version
When you are nished making your selections, press the Add or Save button to create or save the RF Options
Maintenance settings.
Setting up ACCU-DART